You flip on the lights before opening and the neon in the front window just sits there. Or half the word is lit and the other half is dark. Or one letter is glowing a weird washed-out pink. You've got customers in an hour and you're wondering if this is a five-minute fix or a new sign.
Most of the time it's neither. After 35 years of fixing Chicago neon, we can tell you that a surprising number of "broken" signs are a tripped outlet or a timer that got knocked out of sync. The rest need someone with the right equipment and a glass bench.
Here's how to tell the difference without getting hurt.
You can safely check the power side of a neon sign, but anything past the plug and switch is high-voltage work for a pro.
A neon transformer takes 120 volts in and steps it up to thousands of volts on the output side, typically somewhere between 2,000 and 15,000 volts depending on the sign. That voltage runs through the GTO wire and the electrodes at each end of every tube. It can arc through cracked insulation and it can seriously injure you.
So the rule is simple:
Start with power, because most "dead" neon signs are a power problem, not a neon problem. Work through these in order:
If all of that checks out and the sign is still dark, you've done your part. Our full sign diagnostic guide walks through the same process for every sign type, not just neon.
The pattern of what's lit and what's dark usually points to the cause before anyone opens the sign.
Neon tubes on one transformer are wired in series, like old Christmas lights. If one tube on that circuit cracks or loses its gas, the whole circuit can go dark or start flickering, not just the broken piece. Bigger signs often run several transformers, so you'll see one section out while the rest stays lit.
| Symptom | Likely cause | Owner check or pro job? |
|---|---|---|
| Whole sign dark | No power, tripped GFCI or breaker, timer, or a failed transformer | Check power first; transformer is a pro job |
| One section dark, rest lit | Failed transformer on that circuit, a broken tube, or a wiring fault | Pro job |
| Tube glows pale pink, white or purple instead of its color | Air has leaked in; the tube has lost its gas fill | Pro job (tube must be re-processed) |
| Flickering or sputtering at the tube ends | Worn electrode, loose connection, or a weak transformer | Pro job |
| Sign is dim overall | Aging transformer or tubes near end of life | Pro job |
| Buzzing, hot smell, or tar on the box | Transformer overheating or failing | Turn it off and call |
| Visible crack or broken glass | Physical damage | Turn it off and call |
A tube that changes color is a giveaway. Neon gas glows a distinct red-orange, and blues and other colors come from argon and mercury inside coated glass. When a hairline crack lets air in, the color goes wrong, then the tube stops lighting. If the sign flickers rather than going fully dark, our guide to flickering signs covers the usual suspects.
No — a cracked neon tube has lost its vacuum, and no glue, tape or epoxy will bring it back.
A neon tube works because it's sealed and filled with a small amount of gas at low pressure. Once air gets in, the tube won't light properly, even if the glass looks whole again. Any patch that covers the crack still leaves contaminated gas inside.
The real fix happens on a neon bench:
That's skilled glass work. It's why "neon repair" from a shop that only does LED often means "we'll sell you a new sign."
When the whole sign or one full circuit is dark and power checks out, the transformer is the first suspect. Signs that point to it:
Testing a transformer means measuring output with the right meter, under high voltage, so it's strictly pro work. Modern electronic neon power supplies also have built-in secondary ground-fault protection, which can shut the sign off when it senses a fault in old wiring or a wet tube. Sometimes the "bad transformer" is actually doing its job. We'll cover this in depth in Neon Sign Transformer Replacement: Signs It's Failing & What It Costs (coming soon).
Call as soon as the problem is past the plug, the switch, the breaker and the timer. Stop and call right away if you see:
Don't try to remove tubes or open the transformer box. Unplug it or turn off the circuit and leave the rest to someone with a meter and a bench. For what the actual repairs run, see our neon repair cost breakdown.
Rick Signs and Repairs is a father-and-son shop on Bryn Mawr in Edgewater, fixing signs for Chicago businesses since 1989. Neon is one of the things we do best. We test transformers properly, trace GTO wiring, replace electrodes, and work with glass so broken tubes get re-bent and re-filled instead of thrown out.
If your sign is past the safe checks above, our neon sign repair service covers diagnosis, on-site fixes and bench work across Chicago and the suburbs.
Fixing a neon sign starts with the boring stuff: plug, switch, GFCI, breaker, timer. If those check out, the pattern of what's dark tells you a lot, but the repair itself is high-voltage and glass work. Broken tubes get re-made, not glued, and transformers get tested, not guessed at.
Do the safe checks, then let someone who actually fixes neon take it from there.
Related reading
Neon sign still dark after the safe checks? Call Tymothy at (773) 815-0006 or Rick at (847) 809-7900, or request a quote.